| Control Cables |
Bend Radius
|
Oil Resist. |
Temp Range F |
v max Unsupported |
v max Gliding |
a max |
Torsion Resist. |
# of Conductors |
AWG Range |
CF130: Low-cost, flexing tray cable
Download .PDF file |
10 x |
N |
+23 to +158 |
6.56 ft/s |
3.28 ft/s |
32.8 ft/s |
Y |
2 to 25 |
22 to 10 |
CF140: Low-cost, flexing tray cable with shielding
Download .PDF file |
12-15 x |
N |
+23 to +158 |
6.56 ft/s |
3.28 ft/s |
32.8 ft/s |
N |
3 to 25 |
24 to 14 |
CF130US: Low-cost, flexing tray cable, UL- & CSA-rated
Download .PDF file |
8 x |
Y |
+23 to +176 |
6.56 ft/s |
3.28 ft/s |
32.8 ft/s |
Y |
2 to 33 |
22 to 10 |
CF140US: Low-cost, flexing tray cable with shielding, UL- & CSA-rated
Download .PDF file |
10 x |
Y |
+23 to +176 |
6.56 ft/s |
3.28 ft/s |
32.8 ft/s |
N |
2 to 33 |
22 to 10 |
CF170-D: Regular duty, oil-resistant, DESINA-approved cable
Download .PDF file |
10 x |
Y |
-4 to +176 |
6.56 ft/s |
3.28 ft/s |
3.28 ft/s |
Y |
3 to 30 |
20 to 8 |
CF5: Power/signal cable with PVC jacket
Download .PDF file |
7.5 x |
Y |
+23 to +158 |
32.8 ft/s |
16.4 ft/s |
164 ft/s2 |
Y |
2 to 42 |
20 to 14 |
CF6: Power/signal cable with shielding and PVC jacket
Download .PDF file |
7.5 x |
Y |
+23 to +158 |
32.8 ft/s |
16.4 ft/s |
164 ft/s2 |
N |
3 to 25 |
24 to 14 |
CF7: Power/signal cable with oil resistance and PUR jacket
Download .PDF file |
7.5 x |
Y |
-4 to +176 |
32.8 ft/s |
16.4 ft/s |
164 ft/s2 |
Y |
3 to 25 |
20 to 14 |
CF7-D: Oil-resistant power/signal cable; DESINA approved
Download .PDF file |
7.5 x |
Y |
-4 to +176 |
32.8 ft/s |
16.4 ft/s |
164 ft/s2 |
Y |
7 to 25 |
18 to 16 |
CF8: Power/signal cable with shielding, oil resistance and PUR jacket
Download .PDF file |
7.5 x |
Y |
-4 to +176 |
32.8 ft/s |
16.4 ft/s |
164 ft/s2 |
N |
3 to 24 |
20 to 14 |
CF2: Longest life power/signal cable with shielding
Download .PDF file |
5 x |
Y |
-4 to +176 |
32.8 ft/s |
16.4 ft/s |
164 ft/s2 |
N |
3 to 48 |
26 to 16 |
| CF98: Control cable for reduced bend radius |
4 x |
Y |
-31 to +194 |
32.8 ft/s |
16.4 ft/s |
164 ft/s2 |
Y |
2 to 8 |
26 to 22 |
CF9: Halogen-free cable for extreme temps with a TPE jacket
Download .PDF file |
5 x |
Y |
-32 to +212 |
32.85 ft/s |
16.4 ft/s |
164 ft/s2 |
Y |
3 to 25 |
24 to 2 |
CF10: Halogen-free, shielded cable for extreme temps with TPE jacket
Download .PDF file |
5 x |
Y |
-32 to +212 |
32.8 ft/s |
16.4 ft/s |
164 ft/s2 |
N |
2 to 25 |
26 to 12 |
| Data/Encoder Cables |
Bend Radius |
Oil Resist. |
Temp Range F |
v max Unsupported |
v max Gliding |
a max |
Torsion Resist. |
# of Conductors |
AWG Range |
CF240: Regular duty, control cable with shielding
Download .PDF file |
10 x |
Y |
+23 to +158 |
6.56 ft/s |
9.84 ft/s |
98.4 ft/s |
N |
3 to 24 |
26 to 22 |
CF211 data: Regular duty, twisted pair with overall shield
Download .PDF file |
10 x |
Y |
+23 to +158 |
16.4 ft/s |
9.84 ft/s |
98.4 ft/s |
N |
2 to 28 |
24 to 20 |
CF211 feedback: Regular duty, twisted pair with overall shield
Download .PDF file |
10 x |
Y |
+23 to +158 |
16.4 ft/s |
9.84 ft/s |
98.4 ft/s |
N |
8 to 16 |
26 to 20 |
CF11: Twisted pair with overall shield for extreme temperatures
Download .PDF file |
10 x |
Y |
-31 to +212 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
N |
4 to 36 |
26 to 14 |
CF11-D: Twisted pair with overall shield for extreme temperatures
Download .PDF file |
10 x |
Y |
-31 to +212 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
N |
12 to 16 |
26 to 17 |
CF11-LC: Low capacitance, twisted pair with overall shield
Download .PDF file |
10 x |
Y |
-31 to +158 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
N |
2 to 4 |
20 |
CF11-IB-S: Special bus cable with shielding
|
10 x |
Y |
-32 to +158 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
N |
6 to 9 |
24 to 17 |
CF11-LC-D: Low capacitance, twisted pair with shielding
Download .PDF file |
10 x |
Y |
-32 to +158 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
N |
4 |
24 to 20 |
CF12: Industrial, twisted pair with overall shield
Download .PDF file
| 10 x |
Y |
-31 to +212 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
N |
6 to 28 |
24 to 17 |
CFBUS: DeviceNet cable, aka: trunk-and-drop cables
Download .PDF file |
10 x |
Y |
-4 to +158 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
N |
4 |
thick 18/16
thin 24/22 |
CF14US: CAT 5 ethernet cable for RJ45 connectors
Download .PDF file |
12.5 x |
Y |
-31 to +158 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
N |
4 |
26 |
CF14: CAT 5 ethernet cable
Dowload .PDF file |
12.5 x |
Y |
-31 to +158 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
N |
2 to 4 |
24 |
| Bus/Fiber Optic Cables |
Bend Radius |
Oil Resist. |
Temp Range F |
v max Unsupported |
v max Gliding |
a max |
Torsion Resist. |
# of Conductors |
AWG Range |
CFLG: Fiber optic cable with addtional copper conductors
Download .PDF file |
10 x |
N |
+23 to +158 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
N |
2=cu
2=fiber |
cu = 18
fiber = 200/230µm |
CFLG-6G: Fiber optic cable
Download .PDF file |
15 x |
Y |
+4 to +140 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
N |
6 to 12 |
50/125µm
62.5/125µm |
CFLK: Fiber optic cable with plastic fiber optic conductors
Download .PDF file |
12.5 x |
Y |
-4 to +158 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
N |
1 to 6 |
980/1000µm |
| Koax Cable |
Bend Radius |
Oil Resist. |
Temp Range F |
v max Unsupported |
v max Gliding |
a max |
Torsion Resist. |
# of Conductors |
AWG Range |
CF.Koax: Koax cable
Download .PDF file |
10 x |
Y |
-31 to +212 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
N |
1 to 5 |
30 |
| Servo Cables |
Bend Radius |
Oil Resist. |
Temp Range F |
v max Unsupported |
v max Gliding |
|
Torsion Resist. |
# of Conductors |
AWG Range |
CF21: Shielded servo/power with shielded, twisted pair
Download .PDF file |
7.5 x |
Y |
+23 to +158 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
N |
4 + 2
4 + 2 x 2 |
power = 16 - 4
signal = 22 - 16 |
CF27: Regular-duty servo cable with shielding
Download .PDF file |
7.5 x |
Y |
-4 to +176 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
N |
4 + 2 |
power = 16 - 6
signal = 17 - 16 |
| Power Cables |
Bend Radius |
Oil Resist. |
Temp Range F |
v max Unsupported |
v max Gliding |
a max |
Torsion Resist. |
# of Conductors |
AWG Range |
CF30: Unshielded power cable
Download .PDF file |
7.5 x |
Y |
+23 to +158 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
Y |
4 to 5 |
16 to 1 |
CF31: Shielded power cable
Download .PDF file |
7.5 x |
Y |
+23 to +158 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
N |
4 to 5 |
16 to 2/0 |
CF34: Power cable for low/average temperatures
Download .PDF file |
7.5 x |
Y |
-31 to +194 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
Y |
4 |
16 to 1 |
| CF34-PE/2: TPE power cable with shielding |
10 x |
Y |
-31 to +194 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
Y |
4 |
1 to 3/0 |
CF35: Shielded power cable for low/average temperatures
Download .PDF file |
7.5 x |
Y |
-31 to +212 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
N |
4 |
16 to 6 |
CF300: Single conductor power cables
Download .PDF file |
7.5 x |
Y |
-31 to +158 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
Y |
1 |
10 to 350 MCM |
| CFPE: Single-core cable for heavy duty use |
7.5 x |
Y |
-32 to +212 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
Y |
1 |
4 to 12 |
CF310: Shielded, single conductor power cables
Download .PDF file |
7.5 x |
Y |
-31 to +158 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
N |
1 |
8 to 300 MCM |
| CFCRANE: Medium voltage, shielded, single-core cable |
10 x |
Y |
-13 to +176 |
32.8 ft/s |
16.4 ft/s |
164 ft/s |
N |
1 |
4 to 3/0 |
Airhoses |
CFAir Pneumatic Hose: Highly flexible pneumatic hose for Energy Chains
Download PDF page |