CF885 is the entry point to the chainflex® PVC motor cable range — an unshielded, low-duty cable for connecting drives and motors in energy chains where the flexing is light and the setting is clean and indoor. With a basic flame-retardant PVC jacket and no oil resistance, it's the economical pick for gentle, low-cycle motor connections rather than hard continuous motion.
When to use it: Light, low-frequency flexing of three-phase motor and drive connections in clean, dry indoor machinery — VFD-to-motor runs in woodworking, stone processing, packaging, supply systems, and handling equipment.
When not to use it:
Application areas: VFD and motor connections in woodworking and stone-processing machines, packaging lines, indoor supply systems, and light handling and adjusting equipment in dry, low-cycle installations.
| Double strokes* | 1 million | 3 million | 5 million | |||
|---|---|---|---|---|---|---|
| Temperature, | v max. [m/s] | a max. | Travel | R min. [Factor x d] | R min. [Factor x d] | R min. [Factor x d] |
| from/to [°C] | unsupported | [m/s2] | [m] | |||
| +5 / +15 | 17.5 | 18.5 | 19.5 | |||
| +15 / +60 | 3 | 20 | ≤ 10 | 15 | 16 | 17 |
| +60 / +70 | 17.5 | 18.5 | 19.5 |