- Outer jacket: iguPUR
- Download Data Sheet
- Overall shield
- Flame retardant
- Silicone-free
- UV resistance: Medium
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- chainflex® class: 3.1.3.1
Change Language :
CF896 is the shielded version of CF895 — the same cold- and oil-resistant iguPUR motor cable, with a braided shield for the EMC control that variable-frequency and servo drives need in harsh environments.
When to use it: Light flexing of shielded motor and drive connections in cold, oily, or shaded-outdoor settings — VFD and servo runs on coolant-exposed machine tools and low-temperature equipment.
When not to use it:
Application areas: EMC-critical VFD and servo connections on coolant-exposed machine tools, cold-store and low-temperature equipment, and shaded indoor/outdoor installations.
| Double strokes* | 1 million | 3 million | 5 million |
|---|---|---|---|
| Temperature, | R min. | R min. | R min. |
| from/to [°C] | [Factor x d] | [Factor x d] | [Factor x d] |
| -20 / -10 | 17.5 | 18.5 | 19.5 |
| -10 / +70 | 15 | 16 | 17 |
| +70 / +80 | 17.5 | 18.5 | 19.5 |