CF10 is the shielded counterpart to CF9 — the same maximum-duty TPE cable for the longest, hardest travels, with a braided shield for EMC-critical runs. It shares the PVC- and halogen-free TPE jacket, the 5 × d bend radius, the 1,312 ft (400 m)+ gliding travel, the bio-oil resistance, the -55 °C (-67 °F) static cold rating and +100 °C (+212 °F) ceiling, and the UV resistance — adding noise immunity for control and signal lines on the most demanding axes.
When to use it: The most demanding long-travel, high-cycle flexing where EMC matters and the environment is oily, cold, or outdoor — shielded control runs on long-travel gantries, crane systems, and high-bay warehouses.
When not to use it: When no shield is needed and cost matters (use the unshielded CF9), when you need a UL-listed cable for North American code (use CF10.UL), when the priority is the smallest bend radius in a fine shielded cable (use CF99.PLUS), or when a shielded PVC or PUR cable such as CF6 or CF78.UL would do at lower cost.
Application areas: EMC-sensitive long-travel gantries, crane and hoist systems, high-bay warehouses, and outdoor or cold-environment automation with extreme travel.
| Double strokes* | 5 million | 7,5 million | 12.5 million |
|---|---|---|---|
| Temperature, | R min. | R min. | R min. |
| from/to [°C] | [Factor x d] | [Factor x d] | [Factor x d] |
| -35 / -25 | 6,8 | 7,5 | 8,5 |
| -25 / +90 | 5 | 6 | 7 |
| +90 / +100 | 6,8 | 7,5 | 8,5 |
* Higher number of double strokes possible - use the service life calculation function on this page.